|

RG Cleanroom Grid
Applications include pharmaceutical, food processing, and hospital industries. The
RG system differs from the CG system
in that the 1-1/2" extruded aluminum face tee is
designed with an 1/4" upturned flange and provides a sharp architectural detail.
Panels or filters contact the gasket first to complete a seal prior to settling
on the tee flange. RG provides an upgrade in performance over the more economical
CG System.
Finish
Standard finish is clear satin anodized aluminum, which is recommended for harsh
environments. White Acrylic "Wet" Paint and custom finishes are also available upon
request.
Gasketing
The standard RG Series gasket is a factory applied, 1/4" x 1/2" closed
cell PVC, gray in color, with small cells and a smooth surface. Gaskets are available
with adhesive on one or both sides; polyvinyl, neoprene, polyethylene; anti-bacterial,
and flame retardant. Call Gordon if custom gaskets are required.
Gasket Specifications
- Passes fungus resistance test (Method 508.1 mill-std-810C)
- Flame-resistant (FMYSS #302)
- Shore Hardness (ASTM D-2240) on AA scale is 7; on OO scale is 51
- 8# density per cubic foot
- U.S.D.A. approved
Filter Compatibility
RG systems ar compatible with all major filter manufacturers.
Light Fixture Compatibility
RG systems require fixtures designed specifically for cleanroom applications.
Custom Panels
Custom .032" aluminum panels are manufactured in all sizes to allow for non-standard
module sizes, fill-in perimeter panels, and sprinkler panels.
RG Profile Detail
RG Assembly Detail
TOP
Accessories
|
RG Accessories |
|
MTS-Main Tee Splice |
1 per main tee |
RG-2
Two Way Clips |
1 per cross tee |
RGHC
Hold Down Clips |
as needed for panel security / usually 4 per module |
|
90° Angle Clip |
tee attachment to wall angle |
RG Sliding
Hanger Clips |
optional hanger clip slides along web of the tee allowing hanger wire attachment
when special clearances for filters or fixtures are required |
|
RG Load Table |
|
System
Type
|
Web
Height
|
Span Hanger
Wire Spacing
|
Spacing of
Main Tees
|
Applied Load
(lbs./sq.ft.) |
ASTM
|
|
RG-15 |
1-3/4" |
48" |
24"
48" |
8.9
4.4 |
Heavy Duty
Heavy Duty |
|
RG Parts Specifications |
|
Part Number
|
Description
|
A
Web Depth
|
B
Exposed
Gasketed
Flange
|
Length |
Weight per
linear ft.
w/ gasket
|
Pieces per
carton
w/ gasket
|
Linear feet
per carton
|
|
RG-15-MT4 |
Main Tee |
1-3/4" |
1 1/2" |
12' |
0.31 |
16 |
192 |
|
RG-15-MT2 |
Main Tee |
1-3/4" |
1 1/2" |
12' |
0.31 |
16 |
192 |
|
RG-15-48CN |
Cross Tee
Center
Notch |
1-3/4" |
1 1/2" |
4' |
0.31 |
48 |
192 |
|
RG-15-48NN |
Cross Tee
No Notch |
1-3/4" |
1 1/2" |
4' |
0.31 |
48 |
192 |
|
RG-15-24 |
Cross Tee |
1-3/4" |
1 1/2" |
2' |
0.31 |
48 |
96 |
|
RG-WA-48 |
Wall Angle |
1-1/2" |
3/4" |
12' |
0.23 |
24 |
288 |
|
RG-WA-24 |
Wall Angle |
1-1/2" |
3/4" |
12' |
0.23 |
24 |
288 |
|